Pipes and fittings are connected with Top-Connect push-fit sockets, with no welding or solvent cement on site. Taking full flow, wind load and UV exposure into account, the general rule is a maximum support spacing of 300 cm:
| Pipe DN | Support spacing at full load (drainage), cm | Support spacing at partial load (e.g. cable conduit), cm |
|---|---|---|
| 110–125 | 150 | 150–200 * |
| 160 | 200 | 200–250 * |
| 250 | 250 | 300 * |
| 315–630 | 300 | 300 |
* Longer spacings depend on the actual weight of the line.
Fixed points can be placed up to 12 m apart. Prefabricated support and suspension points avoid drilling or welding of fastenings later. For inspection and cleaning, the POLO-EHP Control cleaning pipe is available from DN/OD 110 to DN/OD 500.
Water from a bridge deck usually needs treatment before it reaches a watercourse. Vesmaco combines the pipe system with stormwater treatment equipment and, where the outflow has to be retained, with storage tanks. Send us the drawings, diameters, lengths and schedule, and we will propose a POLOPLAST solution with a material list.